◇ English language display.
◇ Measure Conductivity/TDS/Resistivity and Temperature.
◇ High/low limit relay control output , 4-20mAcurrent output. digital Modbus RS485 communication output (Optional).
◇ High/low limit alarm light, double relay, alarm delay could be set.
◇ Instrument mode isolated transmitting port, max circle resistance up to 750Ω.
◇ PID control to actuate and control powered variable value through 4-20 mA output (optional).
◇ Back light of LCD could select power saving mode, timing automatic off, brightness adjust.
◇ Conductivity constant input directly function or to calibrate probe constant as per known calibration solution’s conductivity value.
◇ High performance CPU, good electromagnetic compatibility.
◇ MOV and AC input be fused function.
◇ ESD over voltage protection is available.
◇ Password management avoid non-professional person to operate.
Main Technique Specifications
|
Function Model |
EC/TDS/RM-6850 Conductivity /TDS /Resistivity controller |
|
Measuring Range |
Conductivity: 0-200uS ( 0.1sensor), 0-20, 000uS(1.0 sensor), 0-200mS (10.0 sensor) TDS: 0-100ppm(0.1 sensor), 0-10,000ppm(1.0 sensor) Resistivity: 0-18.25MΩ·cm (0.01 sensor) 0-18250KΩ·cm (0.01 sensor) |
|
Accuracy |
+ 1.5% (FS) |
|
Temp. Comp. |
0~120 ℃, Automatic, PT1000 |
|
Sensor constant |
0.01, 0.1, 1.0, 10.0 cm-1 |
|
Sensor connection |
1/2”NPT (standard), 3/4”NPT(optional), Flanged (optional) |
|
Sensor cable length |
5m or as per request |
|
Display |
128 * 64 dot matrix LCD |
|
Current output signal |
Isolated, Transferable 4-20mA signal output, max circle resistance 750Ω |
|
Control output signal |
High/Low Limit relay control output, (3A/250 V AC) |
|
Communication signal |
Modbus RTU RS485 (optional) |
|
Power |
AC 220V ±10%, 50Hz (Standard) AC110V ±10%, 50Hz (Optional) AC/DC 24V(optional) |
|
Working temperature. |
0~60℃, 0~100℃ (Match high temp. Sensor) |
|
Working pressure |
0~0.5MPa |
|
Protection grade |
IP 65 |
|
Working environment |
Ambient Temp. 0~60℃, Relative Humidity ≤95% |
|
Overall dimensions |
96×96×127mm(high×width×depth) |
|
Hole dimensions |
92×92mm(height×width) |
|
Installation Mode |
Panel Mounted(Embeded) |
Application
Widely used for electronic, Chemical, Pharmaceutical, electromechanical, drinking water, cooling tower, boiler plant and other industries for online conductivity, resistivity controller.
Product detail pictures:
Related Product Guide:
It is our responsibility to meet your needs and efficiently serve you. Your satisfaction is our best reward. We are looking forward to your visit for joint growth for China Supplier Electrode - Conductivity TDS Controller EC/TDS-6850 – JIRS , The product will supply to all over the world, such as: Doha, Somalia, Amman, We always adhere to follow the honesty, mutual benefit, common development, after years of development and the tireless efforts of all staff, now has perfect export system, diversified logistics solutions, comprehensive meet customer shipping, air transport, international express and logistics services. Elaborate one-stop sourcing platform for our customers!
Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.