We keep improving and perfecting our products and service. At the same time, we work actively to do research and development for Inline Transmitter , Colorscreen Ro Controller , Two Wires Ph Orp Transmitter Controller , We sincerely welcome friends to negotiate business and start cooperation. We hope to join hands with friends in different industries to create a brilliant future.
OEM Customized Greenhouse Hydroponic Ph Ec - Online Conductivity TDS Sensor CR-102P – JIRS Detail:

Pls unpack and check that the sensor has been supplied undamaged and that it is the correct option as ordered. If you have any problems please contact your supplier.

Application
Widely used for industrial water, tap water, cooling water, pure water etc. Conductivity measurement.

Main technique specification

Name

Function

Cell Constant

0.05cm-1  ( v )

0.1cm-1  (  )

1.0cm-1  (  )

10.0cm-1 (  )

Electrode structure

Bipolar

Electrode material

ABS (   )

316L Stainless steel(  v )

Temperature Sensor

NTC 10K ( v )

Pt 1000  (  )

 Pt 100  (  ) 

Thread structure

½” NPT Thread

Working pressure

0~0.5MPa

Operating temperature

0~50℃

Cable length

Standard:5m or others(5-30m)

Dimensions drawing
Conductivity-meter5

Conductivity(TDS)/ Resistivity electrode dimensions 

Installation and maintenance
Installation: To ensure the real measurement result, data distortion caused by air bubble or dead water in conductance cell should be avoided. The installation should be performed strictly according to the following drawing:

Conductivity-meter6

Notes
1. The electrode should be installed at a lower location in the pipe where the flow speed is steady and air bubbles are seldom generated.
2. No matter the conductance cell is horizontally or vertically installed, it should be deeply inserted into the moving water.
3. The conductivity/Resistivity signal is weak electronic signal and its collecting cable should be separately installed.
When threading cable joint or connecting terminal board is used, to avoid wetting interference or breakdown of measurement unit circuit, they should not be connected to the same group of cable joint or terminal board with the power or control line.
4. When the measurement cable needs to be lengthened, it’s recommended to use the cable provided by the original manufacturer, and the joint should be subject to reliable damp-proofing insulation disposal. When a longer distance is involved, the length of the cable (<30m) should be agreed on before delivery, and if the length is over 30m, a transmitter should be used.

Electrode Maintenance
1. The electrode cell should not be soaked in strong acid or alkali liquid, and the platinum black coating should not be wiped or it will lead to electrode surface damage and the constant and response capability will be affected. The right way should be: when the electrode is dirty, soak it in 10% dilute hydrochloric acid for a short while, then rinse it with pure water to keep the surface clean.
2. The measurement cable is special cable and should not be changed at will or it will cause significant error.

Joint wire
white wire to Cell -INPUT
Yellow wire to Cell -OUPUT
Black wire-TEMP
Red wire-TEMP

JiShen Water treatment Co., Ltd.
Add: No.18, Xingong Road, High-Technology Area, Shijiazhuang,China
Tel: 0086-(0)311-8994 7497 Fax:(0)311-8886 2036
E-mail:info@watequipment.com
Website: www.watequipment.com


Product detail pictures:

OEM Customized Greenhouse Hydroponic Ph Ec - Online Conductivity TDS Sensor CR-102P – JIRS detail pictures

OEM Customized Greenhouse Hydroponic Ph Ec - Online Conductivity TDS Sensor CR-102P – JIRS detail pictures

OEM Customized Greenhouse Hydroponic Ph Ec - Online Conductivity TDS Sensor CR-102P – JIRS detail pictures


Related Product Guide:

"Based on domestic market and expand overseas business" is our improvement strategy for OEM Customized Greenhouse Hydroponic Ph Ec - Online Conductivity TDS Sensor CR-102P – JIRS , The product will supply to all over the world, such as: Leicester, Pakistan, France, The development of our company not only needs the guarantee of quality, reasonable price and perfect service, but also relies on our customer's trust and support! In the future, we will continue with the most professional and high quality service to provide the most competitive price, Together with our customers and achieve win-win! Welcome to inquiry and consult!
  • The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Doreen from Slovenia - 2018.06.09 12:42
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Ophelia from Czech Republic - 2017.05.02 11:33
    Write your message here and send it to us