JIRS-PH-D -pH sensorem

Description:

PPH-500 pH Sensor Manual


Product Detail

Product Tags

Caput 1 Specification

Specification Singula
Potestas Supple 12VDC
Magnitudo Diameter 30mm*Length195mm
Pondus 0.2KG
Principalis Material Polypropylene operculum nigrum, Ag/Agcl referat gel
IMPERVIUS Grade IP68/NEMA6P
Mensuratio dolor 0-14pH
Mensuratio Accuracy ±0.1pH
Pressura dolor ≤0.6Mpa
Alkali Error 0.2pH(1mol/L Na+pH14)(25℃)
Mensurans Temperature Range 0 ~ 80
Nulla potentia pH Value 7±0.25pH(15mV)
Clivo ≥95%
Resistentia interna ≤250MΩ
Responsio tempus Minus quam X seconds (perveniens ad endpoint XCV%) (post concursum facientem)
Longitudo cable Funis Latin longitudo est 6 metrorum, quae extenditur.

Sheet 1 Specification of PH Sensor

Specification Singula
Potestas Supple 12VDC
Output MODBUS RS485
Praesidium Gradus IP65, potest consequi IP66 post potting.
Operating Temperature 0℃ - +60℃
Repono Temperature -5℃ - +60℃
Umor Nulla condensatio in latitudine 5%~90%
Magnitudo XCV * XLVII * 30mm (Longitudo * Latitudo altitudo)

Sheet 2 Specification of Analog-ad-Digital Conversion Module

Praevia notitia nulla est si aliqua specificatio producti mutationes.

Caput II Product Overview

2.1 Product Information
pH Potentia Hydrogenii aquae corporis eiusque praecipuas proprietates describit.Si pH est minor quam 7.0, significat aquam acidicam esse;Si pH aequatur 7.0, significat aquam neutram esse, et si pH plus quam 7.0, aqua alkalina est.
Sensor pH utitur composito electrode, quod vitrum designat electrode et comparatione electrode ad pH aquae metiendum utitur.Data est stabilis, certa effectus est, et simplex institutionis est.
In his agris late adhibetur ut purgamentorum plantarum, operum aquarum, stationum aquarum, superficies aquarum et industriarum;Figura 1 praebet ducta dimensiva quae sensoris magnitudinem ostendit.

JIRS-PH-500-2

Figura I magnitudinem sensorem

2.2 Salutis Information
Hoc manuale omnino lege quaeso antequam sarcinam aperias, inaugurando vel utendo.Alioquin potest causare personalem iniuriam operanti vel armorum damnum inferre.

Monitum pittacia

Quaeso lege omnia pittacia et signa in instrumento, et praeceptis pittacii securitatis parere, alioquin iniuriae vel armorum damnum causare potest.

Cum hoc symbolum in instrumento apparet, placet referre ad operationem vel salutem informationem in relatione manuali.

Dum hoc symbolum indicat impulsum electricum vel periculum mortis ab ictu electrico.

Hoc manual perfecte lege quaeso.Praesertim notas vel admonitiones, etc. Ut caveat ne subsidia in apparatu provisa tollantur.

Chapter 3 Installation
3.1 instruitur sensoriis
Certae institutionis gradus haec sunt:
a.Instrue 8 (platea conscendens) in clausura piscinae cum 1 (fibulae M8 U-figura) ad sensorem ascendentem;
b.Coniungere 9 ad 2 (DN32) fistulam PVC glutine, dilabi sensorem per fistulam Pcv, donec cochleis sensoriis in 9 (adaptor), et curationem IMPERVIUS facias;
c.Fige 2 (DN32 tube) super 8 (laminam ascendentem) ab 4 (DN42U-figura Fibulae).

JIRS-PH-500-3

Figura II Schematic Diagram in institutione sensoris

1-M8U-figura Clamp(DN60 2- DN32 Pipe (extra diametrum 40mm)
3 Hexagon Pentium Screw M6 * CXX " 4-DN42U-figura Pipe Clip
5- M8 Gasket(8*16*1) 6- M8 Gasket(8*24*2)
7. M8 vere Shim 8- Adscendens Plate
IX-Adaptor (Stread to Rectus-per)

3.2 Sensor Vinculum
(1) Primum, Coniunge sensorem iungendi analog-ad-digitalem moduli convertentis, ut infra ostendetur.

JIRS-PH-D-4
JIRS-PH-D-5

(2) Et tunc respective nucleum funis post moduli definitionem core iungo. Recta connexio inter sensorem et definitionem core:

Serial numerus 1 2 3 4
Sensor Wire Brown nigreos caeruleum flavus
Signum +12VDC AGND RS485 A RS485 B

(3) PH analog-ad-digitalum e moduli convertentis iuncturam breviorem calorem recusabilem fistulam ad grounding adhiberi potest. Cum usus caloris horrendae fistulae secari debet, ostendens lineam rubram ad terram.

JIRS-PH-500-6

Caput IV Interface et Operatio
4.1 User Interface
① Sensor utitur RS485 ad USB ad connexionem cum computatro, et tunc CD-ROM programmatis modbus Poll ad instituendum computatorium superiorem, geminus-click et Mbpoll.exe exequi ut prompta institutionis, tandem, intrare potes. user interface.
② Si primum est, debes primum subcriptio.Preme "Connexionem" in bar menu et primam lineam in tabula gutta-down eligere.Connection Setup ostendet alternis buxum pro adnotatione.sicut figura patebit.Effingo adnexa adnotatione code ad Registration Key ac preme "OK" ad perficiendam adnotationem.

JIRS-PH-500-7

4.2 Parameter Profecti
1. Preme in talea menu, elige Lege / Scribe Definitionem, tum preme OK post figuram infra sequentem ut optiones ponas.

JIRS-PH-500-8

Nota:Defalta initialis servi inscriptio (Servi ID) est 2, et cum servi inscriptio mutatur, servus inscriptionem novam cum inscriptione communicatur et altera servi inscriptio est etiam recentissima inscriptione mutata.
2. Connexionem in menu talea strepita, primam lineam in menu Connection gutta-down posita, pone ut Figura infra ostendetur, et deprime OK.

JIRS-PH-500-9

Nota:Portus ponitur iuxta portum numerorum nexum.
Nota:Si sensorem connexum sicut descriptum est et status programmatis ostensionis apparet Nulla Connectio, significat illam non connexam.Portum USB remove ac reponere vel converter USB ad RS485 reprehendo, priorem operationem repetes donec nexus sensoris succedat.

Caput V Calibratio Sensoris
5.1 Praeparatio ad Calibration
Ante probationem et calibrationem aliqua praeparatio facienda est ad sensorem, quae talis est:
1) Priusquam experimentum, dimovere testam utrem vel globulus macerari, quae electronico ab solutione macri protegendi adhibita sunt, mensurationem electrodis in aquam destillatam immergas, move et munda;deinde e solutione electrodam collige, et aqua decocta cum charta colum emunda.
2) Animadverte intus bulbi sensitivi, ut videas si plena fuerit liquida, si bullae inventae fuerint, terminatio electronici metiendi deorsum leniter (sicut thermometrum quassatio corporis) ad bullas intra bulbum sensitivum removendum; secus subtiliter experiendi afficiet.

5.2 PH Calibration
PH sensorem calibrated ante usum oportet.Sui calibratiis fieri potest ut sequens ratio.pH calibratio postulat 6.86 pH et 4.01 pH solutionem vexillum quiddam, gradus specifici sunt hoc modo:
1. Sensorem ad PC coniunge ut nexum verum sit et deinde eam in solutione quiddam cum pH 6.86 imponat et in solutione opportuno rate moveat.
2. Post datas stabilit, duplices click notitias derectas in latere dextro 6864 et solutionem quiddam valorem 6864 (solutions cum pH 6.864) repraesentans in tabula solutionis neutrae calibrationis, ut in sequenti figura ostenditur. ac deprime Mitte.

JIRS-PH-500-10

3. specillum aufer, specillum aqua deionata ablue, et aqua residua colum chartam munda;deinde pone in solutione quiddam cum pH 4.01 et in solutione opportuno rate excita.Exspecta donec notitia stabiliatur, duplices click thecam datae a dextra parte 4001 et solutionem quiddam 4001 imple (pH 4.001) in acidi solutionis calibrationis mandare, ut in sequenti figura ostenditur, et tunc strepita. Mitte.

JIRS-PH-500-11

4. Post punctum acidum solutio calibrationis absolvetur sensor aqua destillata lavabitur et siccabitur;tunc sensorem cum solutione probata explorari potest, valorem pH notare postquam confirmatae est.

Caput VI Protocollum Communicationis
A.Analog-ad-digitalis conversio moduli cum MODBUS RS485 munus communicationis, RTU modum communicationis adoptat, cum haud rate ad 19200 perveniat, tabella specifica MODBUS-RTU talis est.

MODBUS-RTU
Baud rate 19200
Data Bits 8 bit
Pari Moderare no
Bit nolite 1bit

B. MODBUS protocollum adoptat, et singula quae in tabula infra monstrantur.

PH Lectio Data
Oratio Data Type Data Forma Memo
0 Float II numeri post punctum punctum validi sunt PH Value(0.01-14)
2 Float I digiti punctum post punctum valet Temperatus Value(0-99.9)
9 Float II numeri post punctum punctum validi sunt Deviatio Value
Calibration of PH optiones
5 Int 6864 solutio cum pH 6,864). Calibration Solutio Neutralis
6 Int 4001 solutione cum pH 4.001)) Calibration Acidum Solutio
9 Float9 -14 ad + 14 Deviatio Value
9997 Int 1-254 OMNIBUS Oratio

Caput VII De cura et sustentatione
Ad optimos exitus mensurae obtinendas, cura et conservatio regularis valde necessaria est.Cura et conservatio maxime includunt conservationem sensoris, reprehendo sensorem ad videndum an laedatur vel non sit, et sic de aliis.Interea status sensoris in cura et inspectione observari potest.

7.1 Sensor Purgatio
Post longum tempus utendum, clivus et responsio celeritas electrodis fortasse retardabit.Mensuratio terminalis electrodis in 4% HF immergi potest pro 3~5 secundis vel solutione HCl diluti pro 1~2 minutis.Lavatur deinde aqua destillata in potassae chloridi (4M) solutione et macerato per 24 horas vel amplius ut novum fiat.

7.2 De conservatione sensoria
Durante periodo interstitiali usuum electrodis, conare mundare terminum mensurae electrodis cum aqua destillata.Si electronico non longo tempore utendum est;lavari et siccari debet, et in utre maculoso apposito vel cum operculo iuvantis adnexo in quo crapulam solvi debet.

7.3 inspectionem de damno sensoriis
Reprime speciem bulbi sensoris et vitrei ut videas si laedantur vel non sint, si damna inveniantur, necesse est sensorem in tempore reponere.In solutione probata, si substantias sensitivas bulbi vel juncturas interclusio contineat, relicto electrode passione, phaenomenon est tempus responsionis significanter tardior, declivia reductionis vel lectionum instabilis.Quam ob rem, natura horum contaminantium innititur, apta uti solvendo ad purgandum, ita nova faciens.Contaminantes et opportuna Detergents infra ad referentiam recensentur.

Contaminantes Detergents
Metallic Oxide 0.1 mol/L HCl
Organicum Grease substantia Debilis Alkalinity vel purgat
Resina, Maximum hypotheticum Hydrocarbonum Sin, Acetone et Ethanol
Dapibus Sanguinis Depositum Acidum Enzyme SOLUTIO
Dyestuff substantia Liquidum acidum dilutum hypochlorum

Caput VIII Post-venditio Service
Si quas quaestiones habes vel officium reparandi opus est, pete nobis ut sequentia.

JiShen aqua curatio Co, Ltd.
Add:No.2903, Aedificium 9, C Area, Yuebei Park, Fengshou Road, Shijiazhuang, Sinis .
Tel:0086-(0)311-8994 7497 Fax:(0)311-8886 2036
E-mail:info@watequipment.com
Website: www.watequipment.com


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis